Précédent
Suivant

QEED QA-OMNI UNIVERSAL SIGNAL CONVERTER 4 voies isolé - RS485 MODBUS- Enregistreur de données

SKU QEED QA-OMNI Catégorie Analyseurs d'énergie
161,00 €
HT

Livraison:

-

QEED QA-OMNI UNIVERSAL SIGNAL CONVERTER 4 voies isolé - RS485 MODBUS- Enregistreur de données

Advanced UNIVERSAL SIGNAL CONVERTER, configurable par USB, montage sur rail DIN, isolé galvaniquement à 4 voies, alimentation universelle AC / DC, contact d’alarme programmable, RS485 Modbus.

DATALOGGING via USB avec mémoire de clé USB et téléchargement des données de stockage sur des fichiers importables Excel.  RTC Real Time Clock integré.  COURANT, TENSION, FRÉQUENCE,

POTENTIOMÈTRE, TEMPÉRATURE (RTD et TC tous types).

Related Products

VOLTAGE:

up to 10 Vdc programmable, input impedence 100 KOhm, 1mV

resolution.

CURRENT:

up to 20 mA programmable, input impedence 20 Ohm, max resolution

2μA.

TEMPERATURE:

RTD: Pt100, Pt500, Pt1000, Ni100. 2,3 or 4 wire measure, automatic

detection of cable interruption.

TC Types: J, K, R, S, T, B, E, N; automatic detection of cable interruption

(-10mV to 70mV).

POTENTIOMETER: from 1000 Ohm to 10 KOhm.

FREQUENCY:

from 0,001 Hz to 9,99KHz, mechanical contact, npn 2 and 3 wires, pnp 3

wires with supply of 24 Vdc, namur, photoelectric, Hall sensor, variable

reluctance, pulse 24 V, TTL.PR SUPPLY

Power Supply: TECTION INDEX

10..40 Vdc, 20-28 Vac, 50-60 Hz

RETRASMISSION OUTPUT:

One isolated analog output,

Voltage and Current (impressed) programmable; Active

or Passive supply output (13 Vdc, 30mA max)

ABSOPRPTION:

Maximum 2,5 VA

Protection Degree:

IP20

ACCURACY :

0.1% Full Scale

RESOLUTION:

16 bit (15 + sign for TC)

REJECTION:

50-60 Hz

THERMAL STABILITY AT 25°C:

< 100 ppm/°C

WORKING TEMPERATURE:

-15...+65°C

STORAGE TEMPERATURE:

-40°C... +85°C

ISOLATION:

Input, analog and digital output,

serial output RS485 and USB port, Power supply, are

4-way galvanically isolated at 1,5kV

HUMIDITY: CCURACY

10...90% non condensing O

ALTITUDE:

Up to 2000 m s.l.m.

MOUNTING:

DIN rail mounting with removable

terminals, RS485 bus and Supply connection ready on

the base of module (connector not included, on request).

CONNECTIONS:

Removable terminals 5,08mm

CE STANDARDS:

EN61000-6-4/2006 + A1 2011;

EN64000-6-2/2005; EN61010-1/2010

DIMENSIONS:

17,5 x 100 x 112 mm (terminals excluded)

DATA LOGGER:

Non-volating memory. Log on USB

OnTheGo port by Pen Drive stick memory. The software

FACILE QA-OMNI (free of charge) allow you to configure

Log, all conversion parameters, set contact alarm, set

Modbus address. RTC Real Time Clock integrated

CONFIGURATION:

By free software FACILE QA-OMNI to configure all of the

conversion parameters like span, zero, alarm contact and

log via USB port or via RS485. Dip-switch for setting

modbus address and baudrate

ELECTRICAL CONNECTIONS:

 

POWER SUPPLY:

10...40 Vdc or 20...28 Vac - Connectors 16 and 17, or by T-BUS connector (optional tool) on the base of the module (see the picture placed on the bottom of this page).

ANALOG INPUT:

depending on the type of sensor or signal available, make the connection as shown. For example, to connect a 3-wire RTD sensor requires a connection to terminals 3, 4 and 6. The Thermocouple, whatever it is, it requires the connection between terminals 3 and 4.

To connect a potentiometer use terminals 3, 4 and 6.

To make resistance measurements at 2, 3 and 4 wires to follow the wiring diagram for the RTD.

For ACTIVE current input use the connectors 2 (positive) and 3. For PASSIVE current input use connectors 2 (positive) and 10 . For Voltage input use connectors 1 (positive) and 3.

DIGITAL INPUT:

the QA-OMNI accepts the input pulses from 0,001 Hz to 9,99 KHz, from mechanical contact, NPN 2 and 3 wire, PNP 3-wire with power supply 24 Vdc, namur, photoelectric sensor, Hall, variable reluctance, pulse 24 V, TTL.

For the connection, refer to the diagram as shown.

ANALOG OUTPUT:

for Voltage analog output, connect terminals 31 and 29 (positive).

For ACTIVE current analog output, connect terminals 29 (positive) and 30. For PASSIVE current analog output, connect terminals 30 (positive) and 31. Analog output supply: 13 Vdc, max 30mA.

DIGITAL OUTPUT:

relay Output SPDT. Connect terminal 25 for Normally Open mode, terminal 26 for Normally Close. The default setting is Normally Open (NO).

SERIAL OUTPUT RS485:

available on connectors 32, 33 (B-), 34 (A+), or by T-BUS connector to be mounted on the module

T-BUS CONNECTION (OPTION), needs T-BUS connector:

It may be affixed to the accessory T-BUS based on the module to bring both power and serial communication. The number of modules supported by the bus is a function of the power supply used (check the absorption of the modules).

 

Rating:
5/5
5 Lire les avis utilisateurs: 1
Commentaires (1)
Note