M-Bus 3 phase kWh meter for CT sec. 5A - MID - EMU Professional II 3/5 P21A000M
Delivery:
Treephase Electricity Meter for external CT with secundar 5A or 1A, M-Bus
Electronic three-phase electricity meter for DIN rail mounting. Detection of active and reactive energy, power factor cos φ, consumption and production (import / export).
MID B & D approved for billing purposes.
Certified for PV systems according to DIN CLC / TR 50579: 2012.
Suitable for energy management systems according ISO50001.
Full compatible with Energy Management System EMU Joulio-Web
Related Products
M-BUS 3 PHASE KWH METER FOR CT SEC. 5A - MID - EMU PROFESSIONAL II 3/5 P21A000M
Product description
The EMU Professional II 3/5 M-Bus is a 3-phase energy meter with MID approval .
The M-Bus communication interface of the 3-phase energy meter EMU Professional II is according to EN13757-2 & EN13757-3, protected against contamination and manipulation.
General information
Measurement
Electronic three-phase electricity meter for DIN rail mounting. Detection of active and reactive energy, power factor cos φ, consumption and production (import / export).
MID B & D approved for billing purposes.
Certified for PV systems according to DIN CLC / TR 50579: 2012.
Suitable for energy management systems according ISO50001.
Full compatible with Energy Management System EMU Joulio-Web
3x230/400VAC, 5A, 50Hz
Integrated manipulation detection. Logging and archiving of configuration changes.
Protection against manipulation by sealable terminal cover.
Technical specifications
Specification | P21A000LO | |
Installation: | 35mm DIN rail. Or front installation by using a mounting frame | |
Width: | 90mm (5TE) | |
Height: | 91mm | |
Depth: | 72mm | |
LCD display: | 38x28mm, 8 digits with backlight | |
Protection class: | Housing IP51, terminals IP20 | |
Environmental conditions: | electrical E2, mechanical M2 | |
Suitable for: | Energy import & export – consumption & production | |
Indication type: | Digital | |
Frequency range: | 40-65Hz | |
Nominal voltage (Un) N-L: | 230V +/-20% | |
Nominal voltage (Un) L-L: | 400V +/-20% | |
Nominal current (In): | 5A | |
Communication interface: | M-Bus interface according to EN13757-2 & EN13757-3, protected against contamination and manipulation. | |
Additional Communication interface: | S0, optical | |
Pulse rate and length: | 1 - 10'000 pulses per kWh / kvarh, adjustable inkl. pulse length | |
Measurable energy and direction: | active and reactive energy, 4 quadrants | |
Energy tariff rates: | 4-tariff | |
Tariff control: | internal | |
Calibrated: | yes | |
Approved: | MID | |
Accuracy class: | B | |
Manipulation protection: | yes | |
Kind of manipulation protection: | sealable terminal cover and integrated manipulation detection |
- BACnet IP gateway function (option)
- OPC UA gateway function (option)
- MQTT (option)
- Modbus TCP (option)
HOW TO CONNECT?
HOW TO PROGRAM?
EMU ENERGY MANAGEMENT AND BILLING
Retrievable measured values on the LoRa electricity meter
· Active power (kw)
· Reactive power (kvar)
· Apparent power (kVA)
· Current (A)
· Active energy consumption (kWh) and supply (kWh)
· Reactive energy consumption (kvarh) and delivery (kvarh)
· Frequency (Hz)
· Number of power failures
S0 pulse output
In addition to the M-Bus interface, the EMU Professional II energy meter has a configurable S0 pulse output
· Active energy consumption or active energy supply
· Reactive energy consumption or reactive energy supply
Factory configuration with direct connection: 1'000 pulses/ kWh, 40 ms
Tariff ConTrol
Tariff changeover takes place by 230VAC to corresponding terminal.
0 = No voltage; 1 = 230VAC,
Tarif changeover connectiondiagram
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent