Previous
Next

M-Bus 3 phase kWh meter 100A - MID - EMU Professional II 3/100 P20A000M

SKU P20A000M Category Energy analysers
€195.00
Tax excluded

Delivery:

if not in stock 2 - 3 weeks

Treephase Electricity Meter up to 100A, M-Bus

Electronic three-phase electricity meter for DIN rail mounting. Detection of active and reactive energy, power factor cos φ, consumption and production (import / export).

MID B & D approved for billing purposes.

Certified for PV systems according to DIN CLC / TR 50579: 2012.

Suitable for energy management systems according ISO50001.

Full compatible with Energy Management System EMU Joulio-Web

Related Products

M-BUS 3/100 EMU PROFESSIONAL II. UP TO 100A MID ELECTRICITY METER P20A000M

Product description

The EMU Professional II 3/100 M-Bus is a 3-phase energy meter with MID approval .

The M-Bus communication interface of the 3-phase energy meter EMU Professional II LoRa is according to EN13757-2 & EN13757-3, protected against contamination and manipulation.

General information

Direct measurement up to 100A.

Electronic three-phase electricity meter for DIN rail mounting. Detection of active and reactive energy, power factor cos φ, consumption and production (import / export).

MID B & D approved for billing purposes.

Certified for PV systems according to DIN CLC / TR 50579: 2012.

Suitable for energy management systems according ISO50001.

Full compatible with Energy Management System EMU Joulio-Web

3x230/400VAC, 100A, 50Hz

Integrated manipulation detection. Logging and archiving of configuration changes.

Protection against manipulation by sealable terminal cover.

Technical specifications

SpecificationP20A000M
Installation:35mm DIN rail. Or front installation by using a mounting frame
Width:90mm (5TE)
Height:91mm
Depth:72mm
LCD display:38x28mm, 8 digits with backlight
Protection class:Housing IP51, terminals IP20
Environmental conditions:electrical E2, mechanical M2
Suitable for:Energy import & export – consumption & production
Indication type:Digital
Frequency range:40-65Hz
Nominal voltage (Un) N-L:230V +/-20%
Nominal voltage (Un) L-L:400V +/-20%
Nominal current (In):100A
Communication interface:

M-Bus interface according to EN13757-2 & EN13757-3, 

protected against contamination and manipulation.

Additional Communication interface:S0, optical
Pulse rate and length:1 - 10'000 pulses per kWh / kvarh, adjustable inkl. pulse length
Measurable energy and direction:active and reactive energy, 4 quadrants
Energy tariff rates:4-tariff
Tariff control:internal
Calibrated:yes
Approved:MID
Accuracy class:B
Manipulation protection:yes
Kind of manipulation protection:sealable terminal cover and integrated manipulation detection

5

  • BACnet IP gateway function (option)
  • OPC UA gateway function (option)
  • MQTT (option)
  • Modbus TCP (option)

HOW TO CONNECT?

HOW TO PROGRAM?

EMU ENERGY MANAGEMENT AND BILLING

Retrievable measured values on the M-Bus electricity meter

·     Active power (kw)

·     Reactive power (kvar)

·     Apparent power (kVA)

·     Current (A)

·     Active energy consumption (kWh) and supply (kWh)

·     Reactive energy consumption (kvarh) and delivery (kvarh)

·     Frequency (Hz)

·     Number of power failures

S0 pulse output

In addition to the M-Bus interface, the EMU Professional II energy meter has a configurable S0 pulse output

·     Active energy consumption or active energy supply

·     Reactive energy consumption or reactive energy supply

Factory configuration with direct connection: 1'000 pulses/ kWh, 40 ms

 

Tariff ConTrol

 Tariff changeover takes place by 230VAC to corresponding terminal.

0 = No voltage; 1 = 230VAC, 

EMU PROFESIONNAL II Tarif changeover connectiondiagram

Tarif changeover connectiondiagram

EMU PROFESIONNAL II Tarif changeover connectiondiagram
Rating:
0/5
Comments (0)
No customer reviews for the moment.